Its uncapped design is optimized for compatibility with 100% pure water (~0% water phase) and provides robust performance even under low pH conditions.

안내사항 |
가격 기재가 되지 않은 별도 문의 상품인 경우 반드시 '온라인 견적문의' 혹은 '전화 문의' 후 구매 부탁드립니다. 설치/교육 신청의 경우 별도의 연락 후 직접 납품 드립니다. |
USHD C18-AR HPLC Column
USHD C18-AR
| Property | USHD C18-AR |
| USP | L1 |
| Pore Size Option | 5 µm, 120 Å |
| 3 µm, 120 Å | |
| 1.8 µm, 120 Å | |
| Surface Area (m²/g) | 320 |
| Carbon Load (%) | 10 |
| pH Tolerance Range | 0.5-8 |
| Column Specifications | 4.6 × 250 mm |
| 4.6 × 150 mm | |
| 4.6 × 100 mm | |
| 4.6 × 50 mm | |
| 3.0 × 100 mm | |
| 3.0 × 50 mm | |
| 2.1 × 100 mm | |
| 2.1 × 50 mm | |
| Features and Applications | >Unique Bonding: Utilizes a specialized bonding process with side chain steric protection. |
| >Water Compatibility: Works seamlessly with 100% pure water (~0% water phase). | |
| >Enhanced Selectivity: Uncapped design provides superior selectivity and unique isomer separation. | |
| >Low pH Stability: Resistant to pH as low as 0.5, ensuring long-term stability in acidic conditions (≤2.0). | |
| >Versatile Separation: Ideal for complex mixtures, effectively separating strongly polar/hydrophilic compounds, non-polar substances, isomers, and peptides. |
Column body
This is a measure of the distribution of particles packed in a column. In HPLC, it is preferable to have narrow particle size distribution as a narrow particle size distribution can lead to better HPLC column efficiency.

Endcap
In LC chromatography the reaction of a silylating agent with unreacted accessible silanols remaining on the silica gel surface after the initial bonding reaction of the HPLC column stationary phase. HPLC column endcapping eliminates unwanted secondary silanol interactions between compounds and the stationary phase.

PEEK frit
Longer filtration life
Consistent frit-to-frit swept volumes
Biocompatible and inert to most solvents
Suitable for low and high pressure applications.
Enhanced sealing and excellent chemical resistance.
PEEK frits can be used up to 80 ºC.


모바일 환경에서는 표를 좌·우로 스크롤해주세요.
고객센터
배송안내
배송기간
주의사항

안내사항 |
가격 기재가 되지 않은 별도 문의 상품인 경우 반드시 '온라인 견적문의' 혹은 '전화 문의' 후 구매 부탁드립니다. 설치/교육 신청의 경우 별도의 연락 후 직접 납품 드립니다. |
USHD C18-AR HPLC Column
USHD C18-AR
| Property | USHD C18-AR |
| USP | L1 |
| Pore Size Option | 5 µm, 120 Å |
| 3 µm, 120 Å | |
| 1.8 µm, 120 Å | |
| Surface Area (m²/g) | 320 |
| Carbon Load (%) | 10 |
| pH Tolerance Range | 0.5-8 |
| Column Specifications | 4.6 × 250 mm |
| 4.6 × 150 mm | |
| 4.6 × 100 mm | |
| 4.6 × 50 mm | |
| 3.0 × 100 mm | |
| 3.0 × 50 mm | |
| 2.1 × 100 mm | |
| 2.1 × 50 mm | |
| Features and Applications | >Unique Bonding: Utilizes a specialized bonding process with side chain steric protection. |
| >Water Compatibility: Works seamlessly with 100% pure water (~0% water phase). | |
| >Enhanced Selectivity: Uncapped design provides superior selectivity and unique isomer separation. | |
| >Low pH Stability: Resistant to pH as low as 0.5, ensuring long-term stability in acidic conditions (≤2.0). | |
| >Versatile Separation: Ideal for complex mixtures, effectively separating strongly polar/hydrophilic compounds, non-polar substances, isomers, and peptides. |
Column body
This is a measure of the distribution of particles packed in a column. In HPLC, it is preferable to have narrow particle size distribution as a narrow particle size distribution can lead to better HPLC column efficiency.

Endcap
In LC chromatography the reaction of a silylating agent with unreacted accessible silanols remaining on the silica gel surface after the initial bonding reaction of the HPLC column stationary phase. HPLC column endcapping eliminates unwanted secondary silanol interactions between compounds and the stationary phase.

PEEK frit
Longer filtration life
Consistent frit-to-frit swept volumes
Biocompatible and inert to most solvents
Suitable for low and high pressure applications.
Enhanced sealing and excellent chemical resistance.
PEEK frits can be used up to 80 ºC.


모바일 환경에서는 표를 좌·우로 스크롤해주세요.
고객센터
배송안내
배송기간
주의사항
티디엘사이언스
대표이사 : 짠드억로이
주소 : 경기도 화성시 경기대로 1014, 6층 603-93호(병점동, 병점프라자)
전화 : 031-232-6799|팩스 : 031-8057-6779
이메일 : tdl-sci@naver.com