USHD Bio-SEC Column is specifically engineered for the precise molecular weight analysis of macromolecular biological samples, including proteins, nucleic acids, enzymes, antibodies, peptides, and ADC drugs.
Utilizing a specialized bonding process, it minimizes sample adsorption, ensures stable batch-to-batch reproducibility, and extends column lifespan—ideal for applications such as monoclonal antibody (mAb) drug development.

안내사항 |
가격 기재가 되지 않은 별도 문의 상품인 경우 반드시 '온라인 견적문의' 혹은 '전화 문의' 후 구매 부탁드립니다. 설치/교육 신청의 경우 별도의 연락 후 직접 납품 드립니다. |
USHD SEC-Bio HPLC SEC Columns
SEC-Bio
| Property | USHD Bio-SEC Series |
| Size Exclusion Chromatography Column | |
| USP | L33 / L59 |
| Pore Size Option | 5 µm, 120 Å |
| 5 µm, 300 Å | |
| 3 µm, 300 Å | |
| Surface Area (m²/g) | / |
| Carbon Load (%) | / |
| pH Tolerance Range | 2-8 |
| Column Specifications | 7.8× 300 mm |
| 4.6 ×300 mm | |
| Features and Applications | Ideal for Biomolecular Analysis: Designed for the detection of macromolecular biological samples, including proteins, nucleic acids, antibodies, enzymes, peptides, and ADC drugs. |
| Supports Biopharmaceutical Applications: Suitable for molecular weight analysis in monoclonal antibody (mAb) drug development and related research. | |
| Ultra-Low Adsorption: Minimizes interaction with biological samples for more accurate and reproducible results. | |
| Special Bonding Process: Significantly reduces dead adsorption and extends chromatographic column life. | |
| High Batch-to-Batch Consistency: Delivers stable and reliable performance across multiple runs. | |
| Available Pore Sizes for Specific MW Ranges: | |
| 120Å: Globular proteins from 100 – 100,000 Da | |
| 300Å: Globular proteins from 5,000 – 1,250,000 Da |
Column body
This is a measure of the distribution of particles packed in a column. In HPLC, it is preferable to have narrow particle size distribution as a narrow particle size distribution can lead to better HPLC column efficiency.

Endcap
In LC chromatography the reaction of a silylating agent with unreacted accessible silanols remaining on the silica gel surface after the initial bonding reaction of the HPLC column stationary phase. HPLC column endcapping eliminates unwanted secondary silanol interactions between compounds and the stationary phase.

PEEK frit
Longer filtration life
Consistent frit-to-frit swept volumes
Biocompatible and inert to most solvents
Suitable for low and high pressure applications.
Enhanced sealing and excellent chemical resistance.
PEEK frits can be used up to 80 ºC.


모바일 환경에서는 표를 좌·우로 스크롤해주세요.
고객센터
배송안내
배송기간
주의사항

안내사항 |
가격 기재가 되지 않은 별도 문의 상품인 경우 반드시 '온라인 견적문의' 혹은 '전화 문의' 후 구매 부탁드립니다. 설치/교육 신청의 경우 별도의 연락 후 직접 납품 드립니다. |
USHD SEC-Bio HPLC SEC Columns
SEC-Bio
| Property | USHD Bio-SEC Series |
| Size Exclusion Chromatography Column | |
| USP | L33 / L59 |
| Pore Size Option | 5 µm, 120 Å |
| 5 µm, 300 Å | |
| 3 µm, 300 Å | |
| Surface Area (m²/g) | / |
| Carbon Load (%) | / |
| pH Tolerance Range | 2-8 |
| Column Specifications | 7.8× 300 mm |
| 4.6 ×300 mm | |
| Features and Applications | Ideal for Biomolecular Analysis: Designed for the detection of macromolecular biological samples, including proteins, nucleic acids, antibodies, enzymes, peptides, and ADC drugs. |
| Supports Biopharmaceutical Applications: Suitable for molecular weight analysis in monoclonal antibody (mAb) drug development and related research. | |
| Ultra-Low Adsorption: Minimizes interaction with biological samples for more accurate and reproducible results. | |
| Special Bonding Process: Significantly reduces dead adsorption and extends chromatographic column life. | |
| High Batch-to-Batch Consistency: Delivers stable and reliable performance across multiple runs. | |
| Available Pore Sizes for Specific MW Ranges: | |
| 120Å: Globular proteins from 100 – 100,000 Da | |
| 300Å: Globular proteins from 5,000 – 1,250,000 Da |
Column body
This is a measure of the distribution of particles packed in a column. In HPLC, it is preferable to have narrow particle size distribution as a narrow particle size distribution can lead to better HPLC column efficiency.

Endcap
In LC chromatography the reaction of a silylating agent with unreacted accessible silanols remaining on the silica gel surface after the initial bonding reaction of the HPLC column stationary phase. HPLC column endcapping eliminates unwanted secondary silanol interactions between compounds and the stationary phase.

PEEK frit
Longer filtration life
Consistent frit-to-frit swept volumes
Biocompatible and inert to most solvents
Suitable for low and high pressure applications.
Enhanced sealing and excellent chemical resistance.
PEEK frits can be used up to 80 ºC.


모바일 환경에서는 표를 좌·우로 스크롤해주세요.
고객센터
배송안내
배송기간
주의사항
티디엘사이언스
대표이사 : 짠드억로이
주소 : 경기도 화성시 경기대로 1014, 6층 603-93호(병점동, 병점프라자)
전화 : 031-232-6799|팩스 : 031-8057-6779
이메일 : tdl-sci@naver.com